Gas Parameter
u Measurement Principle:
Micro-Flow NDIR : SO2,NO,CO,CO2
Electrochemistry: O2
u Measurement Range :
SO2:0-2000PPM
NO: 0-2000PPM
CO: 0-5000PPM
CO2:0-25%
O2: 0-25%
u Resolution:
SO2/NO/CO: 1PPM
CO2/O2: 0.01%
u Precision:
SO2,NO,CO,CO2 : 1%FS
O2: 2%FS
Temperature Parameter
u Measurement Principle:
Ambient Temperature:Thermistor
Flue Gas Temperature: Thermocouple
u Range:
Ambient Temperature :-10-100℃
Flue Gas Temperature : -10-600℃
u Resolution:
Ambient Temperature 1℃
Flue Gas Temperature 1℃
u Precision:
Ambient Temperature ±1℃
Flue Gas Temperature ±2℃
Pressure Parameter:
u Measurement Principle:
Diff. Pressure: Silicon Diff. Pressure Chip
Ambient Pressure: Silicon Pressure Chip
u Range:
Diff. Pressure:-50hPA ...+50hPA
Ambient Pressure: 70KPA...120KPA
u Resolution:
Diff. Pressure: 1PA
Ambient Pressure: 0.01KPAR
u Precision:
Diff. Pressure: ±2PA or 5%REL
Ambient Pressure: ±0.5 Kpa or 2 % rel.